Datamax-oneil Class Series II Programmer’s Manual Uživatelský manuál Strana 135

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 334
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 134
Extended System-Level Command Functions
Class Series 2 Programmer’s Manual 121
STX KuR Read Data from RFID Tag
(Direct Mode – UHF Interface – Hexadecimal Data Only)
This command instructs the RFID device to read data from the tag and then place that
data into a replaceable field. It is expected that the tag transponder is within the read /
write distance of the RFID programming device; otherwise, “Void” will be printed in the
text or bar code label field(s).
Syntax:
<
STX>Ku
R
a
a
<
CR
>
Where:
aa
-
Field number in which to place the data (must be 01,
02, 03, etc.) matching the order of Label Formatting
command, U.
A 00 value will send the ID to the host with no
printing.
Sample:
<STX>L
D11
1911A1801000100 xxxxxxxxxxxxxxxx
U
1A31050002000200 xxxxxxxxxxxxxxxx
U
X
<STX>KuR01
<STX>Kur02
<STX>G
The sample above creates a replaceable text field (01) and bar
code field (02) and then recalls the data from the tag and places it
into the specified fields.
Data should be at least 16 or 24 characters in length.
Zobrazit stránku 134
1 2 ... 130 131 132 133 134 135 136 137 138 139 140 ... 333 334

Komentáře k této Příručce

Žádné komentáře